Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more
information.
$27,276.49 / EA
manufacturer discounts
learn about discounts
- $24,454.78 for $1,500.00+
- $23,514.21 for $2,500.00+
- $22,573.64 for $3,500.00+
In stock (0)
Lead time: over 7 days
may be longer on small orders
Enclosed soft starter, Controller 3RW44366BC34, H2 Std. duty current rating 145A, Control voltage 115 AC, Non-combination type, Enclosure type 3/3R, Weather proof outdoor use
Enclosed soft starter, Controller 3RW44366BC34, H2 Std. duty current rating 145A, Control voltage 115 AC, Non-combination type, Enclosure type 3/3R, Weather proof outdoor use
150
- UPC
- 783087825956
- Certificate of suitability:
- NEMAICS2;UL508A
- Configuration of control input / 1:
- FactorysetasSTARTMOTOR
- Configuration of relay output / 1:
- FactorysetasON-TIMEMOTOR
- Configuration of relay output / 2:
- programmable
- Configuration of relay output / 3:
- programmable
- Configuration of relay output / 4:
- FactorysetasGROUPERROR
- Design of power semiconductors (thyristors) / for soft starter control:
- 3controlledphases
- Design of the fuse link / for short-circuit protection of the main circuit / required:
- 10kA@600V(ClassHorK);100kA@600V(ClassRorJ)
- Design of the housing:
- Weatherproofforoutdooruse
- Design of the product:
- Enclosedsoftstarter
- Design of the short-circuit trip:
- Thermalmagneticcircuitbreaker
- Display version:
- Graphicdisplay
- Manufacturer's article number / of soft starter:
- 3RW44366BC34
- Material / of the conductor / for load-side outgoing feeder:
- CU
- Material / of the conductor / for supply:
- CU
- Mounting type:
- Surfacemountingandinstallation
- Operating condition / for severe duty:
- Class20severeduty(350%ofmotorFLAfor20seconds)
- Operating condition / for standard duty:
- Class10standardduty(350%ofmotorFLAfor10seconds)
- Product designation:
- Enclosedsoftstarter
- Product function:
- Enclosedsoftstarter
- Reset function:
- Manualandautomatic
- Size of contactor:
- NA
- Special product feature:
- Controltransformer,built-inoverloadrelayandbypasscontactorincluded.
- Starting voltage [%] / minimum:
- 20 %
- Stopping voltage [%] / maximum:
- 100 %
- Trip CLASS:
- Class5/10/15/20/30
- Type of communication / optional:
- WithoptionalProfibusorProfinet
- Type of connectable conductor cross-section / for AWG conductors / for line-side / single or multi-stranded:
- 300MCM...6AWG
- Type of connectable conductor cross-section / for AWG conductors / for load-side outgoing feeder / single or multi-stranded:
- 7...2/0AWG(frontonly)or6...2/0AWG(backonly)or2x1/0AWG(bothfront&back)
- Type of cooling:
- None
- Type of electrical connection / for auxiliary and control current circuit:
- screw-typeterminals
- Type of electrical connection / for load-side outgoing feeder:
- Boxlug
- Type of electrical connection / for supply voltage infeed -> line-side:
- Boxlug
- Type of voltage / of the control supply voltage:
- AC
- country of origin:
- USA
- mounting position:
- Vertical
- product brand name: