3M™ Heat Shrink Cable Breakout Boot 2 insulates and seals cable breakouts in multi conductor armored or sheathed cables. This heavy duty boot offers good electrical and mechanical protection. The cross linked, MIL I 81765 1 qualified polyolefin construction is semi rigid and flame retardant.
3M™ Heat Shrink Cable Breakout Boot 2 insulates and seals cable breakouts in multi conductor armored or sheathed cables. This heavy duty boot offers good electrical and mechanical protection. The cross linked, MIL I 81765 1 qualified polyolefin construction is semi rigid and flame retardant.
3M™ Heat Shrink Breakout Boot has an internal coating of adhesive that ensures reliable environmenta...150
3M™ Heat Shrink Breakout Boot has an internal coating of adhesive that ensures reliable environmental sealing of cable breakouts in cables and conduit ends. RoHS 2011/65/EU Compliant.
- Ensures excellent insulation and void-free sealing of cable breakouts
- Internal coating of adhesive offers reliable environmental sealing
- Provides maximum electrical and mechanical protection
- Semi-rigid, flame-retardant polyolefin construction
- Ensures excellent insulation and void-free sealing of cable breakouts
- Internal coating of adhesive offers reliable environmental sealing
- Provides maximum electrical and mechanical protection
- Semi-rigid, flame-retardant polyolefin construction
- UPC
- 054007587958
- UNSPSC
- 39121723
- Country of Origin
- GBR
- Color:
- Black
- Type:
- Breatout Boot
- Color:
- Black
- Type:
- Breatout Boot

46-310
$1.07 /ea
IDEAL, Heat Shrinkable Tube, Thermo-Shrink®, Thin-Wall, Shrink Ratio: 2:1, Outside Diameter: 1/8 IN, Thickness: 017 IN, Length: 6 IN, Volume Resistivity: 1014 OHM CM For ASTM D 876 Test Method, Dielectric Strength: 20 KV/MM For ASTM D 150 Test Method, Continuous Operating Temperature: -55 To 125 DEG C, Minimum Shrink Temperature: 70 DEG C, Heat Shock: No cracking For UL 224(250 DEG C /4 hours), Cable Range: 24 - 20 AWG, Nominal Recoveredi.d. (max.): 063 IN, Expanded I.d. (min.): 0.146, Elongation At Break: 600 PCT For ASTM D 638 Test Method, Elongation Of Break After Aging: 350 PCT For UL 224 Test Method, Cold Bend Test (-55°c/4 Hours): No Cracking For UL 224 Test Method, Copper Corrosion: Pass For UL 224 Test Method, Chemical Resistance: Pass For UL 224 Test Method, Longitudinal Shrinkage: 0 Plus Or Minus 5 PCT For UL 224 Test Method, Eccentricity: 30 PCT For UL 224 Test Method, Normal Size: 1/8 IN, Package: Bag
Attributed Data | Included |
---|---|
Dielectric Strength | 20 KV/MM For ASTM D 150 Test Method Yes |
Heat Shock | No cracking For UL 224(250 DEG C /4 hours) Yes |
Shrink Ratio | 2:1 Yes |
Standard | C/US RU Listed,RoHS Yes |
Sub Brand | Thermo-Shrink® Yes |
Type | Thin-Wall Yes |
Volume Resistivity | 1014 OHM CM For ASTM D 876 Test Method Yes |

46-313
$1.25 /ea
IDEAL, Heat Shrinkable Tube, Thermo-Shrink®, Thin-Wall, Shrink Ratio: 2:1, Outside Diameter: 0.187 IN, Thickness: 020 IN, Length: 6 IN, Volume Resistivity: 1014 OHM CM For ASTM D 876 Test Method, Dielectric Strength: 20 KV/MM For ASTM D 150 Test Method, Continuous Operating Temperature: -55 To 125 DEG C, Minimum Shrink Temperature: 70 DEG C, Heat Shock: No cracking For UL 224(250 DEG C /4 hours), Cable Range: 20 - 14 AWG, Nominal Recoveredi.d. (max.): 094 IN, Expanded I.d. (min.): 0.205, Elongation At Break: 600 PCT For ASTM D 638 Test Method, Elongation Of Break After Aging: 350 PCT For UL 224 Test Method, Cold Bend Test (-55°c/4 Hours): No Cracking For UL 224 Test Method, Copper Corrosion: Pass For UL 224 Test Method, Chemical Resistance: Pass For UL 224 Test Method, Longitudinal Shrinkage: 0 Plus Or Minus 5 PCT For UL 224 Test Method, Eccentricity: 30 PCT For UL 224 Test Method, Normal Size: 3/16 IN, Package: Bag
Attributed Data | Included |
---|---|
Dielectric Strength | 20 KV/MM For ASTM D 150 Test Method Yes |
Heat Shock | No cracking For UL 224(250 DEG C /4 hours) Yes |
Shrink Ratio | 2:1 Yes |
Standard | C/US RU Listed,RoHS Yes |
Sub Brand | Thermo-Shrink® Yes |
Type | Thin-Wall Yes |
Volume Resistivity | 1014 OHM CM For ASTM D 876 Test Method Yes |

46-316
$1.28 /ea
IDEAL, Heat Shrinkable Tube, Thermo-Shrink®, Thin-Wall, Shrink Ratio: 2:1, Outside Diameter: 0.250 IN, Thickness: 022 IN, Length: 6 IN, Dielectric Strength: 20 KV/MM For ASTM D 150 Test Method, Volume Resistivity: 1014 OHM CM For ASTM D 876 Test Method, Continuous Operating Temperature: -55 To 125 DEG C, Minimum Shrink Temperature: 70 DEG C, Heat Shock: No cracking For UL 224(250 DEG C /4 hours), Cable Range: 14 - 8 AWG, Nominal Recoveredi.d. (max.): 022 IN, Expanded I.d. (min.): 0.268, Elongation At Break: 600 PCT For ASTM D 638 Test Method, Elongation Of Break After Aging: 350 PCT For UL 224 Test Method, Cold Bend Test (-55°c/4 Hours): No Cracking For UL 224 Test Method, Copper Corrosion: Pass For UL 224 Test Method, Chemical Resistance: Pass For UL 224 Test Method, Longitudinal Shrinkage: 0 Plus Or Minus 5 PCT For UL 224 Test Method, Eccentricity: 30 PCT For UL 224 Test Method, Normal Size: 1/4 IN, Package: Bag
Attributed Data | Included |
---|---|
Dielectric Strength | 20 KV/MM For ASTM D 150 Test Method Yes |
Heat Shock | No cracking For UL 224(250 DEG C /4 hours) Yes |
Shrink Ratio | 2:1 Yes |
Standard | C/US RU Listed,RoHS Yes |
Sub Brand | Thermo-Shrink® Yes |
Type | Thin-Wall Yes |
Volume Resistivity | 1014 OHM CM For ASTM D 876 Test Method Yes |
Product Image | |||
---|---|---|---|
46-310
IDEAL, Heat Shrinkable Tube, Thermo-Shrink®, Thin-Wall, Shrink Ratio: 2:1, Outside Diameter: 1/8 IN, Thickness: 017 IN, Length: 6 IN, Volume Resistivity: 1014 OHM CM For ASTM D 876 Test Method, Dielectric Strength: 20 KV/MM For ASTM D 150 Test Method...
$1.07 / EA
|
46-313
IDEAL, Heat Shrinkable Tube, Thermo-Shrink®, Thin-Wall, Shrink Ratio: 2:1, Outside Diameter: 0.187 IN, Thickness: 020 IN, Length: 6 IN, Volume Resistivity: 1014 OHM CM For ASTM D 876 Test Method, Dielectric Strength: 20 KV/MM For ASTM D 150 Test Meth...
$1.25 / EA
|
46-316
IDEAL, Heat Shrinkable Tube, Thermo-Shrink®, Thin-Wall, Shrink Ratio: 2:1, Outside Diameter: 0.250 IN, Thickness: 022 IN, Length: 6 IN, Dielectric Strength: 20 KV/MM For ASTM D 150 Test Method, Volume Resistivity: 1014 OHM CM For ASTM D 876 Test Meth...
$1.28 / EA
|
|
Attributed Data | |||
Continuous Operating Temperature | -55 To 125 DEG C -55 To 125 DEG C | ||
Dielectric Strength | 20 KV/MM For ASTM D 150 Test Method 20 KV/MM For ASTM D 150 Test Method | ||
Heat Shock | No cracking For UL 224(250 DEG C /4 hours) No cracking For UL 224(250 DEG C /4 hours) | ||
Length | 6 in 6 in | ||
Minimum Shrink Temperature | 70 DEG C 70 DEG C | ||
Outside Diameter | 0.25 in 0.25 in | 0.125 in 0.125 in | 0.187 in 0.187 in |
Shrink Ratio | 2:1 2:1 | ||
Standard | C/US RU Listed,RoHS C/US RU Listed,RoHS | ||
Sub Brand | Thermo-Shrink® Thermo-Shrink® | ||
Thickness | 017 IN 017 IN | 020 IN 020 IN | 022 IN 022 IN |
Type | Thin-Wall Thin-Wall | ||
Volume Resistivity | 1014 OHM CM For ASTM D 876 Test Method 1014 OHM CM For ASTM D 876 Test Method | ||