$459.61 / EA
In stock (0)
Lead time: over 7 days
may be longer on small orders
3M™ Heat Shrink Cable Sleeve ITCSF is a flexible, thick wall sleeve that provides a high degree of mechanical strength. This sleeve has a 3:1 shrink ratio to offer flame retardant insulation for 1 kV rated applications. It has a cross linked polyolefin construction that provides moisture seal protection.
3M™ Heat Shrink Cable Sleeve ITCSF is a flexible, thick wall sleeve that provides a high degree of mechanical strength. This sleeve has a 3:1 shrink ratio to offer flame retardant insulation for 1 kV rated applications. It has a cross linked polyolefin construction that provides moisture seal protection.
3M™ Heat Shrink Cable Sleeve ITCSF is a split resistant sleeve with a factory applied, adhesive/seal...150
3M™ Heat Shrink Cable Sleeve ITCSF is a split resistant sleeve with a factory applied, adhesive/sealant to offer reliable performance for electrical splices, connections and terminations. It withstands temperatures of 67 to 230 degrees F ( 55 to 110 degrees C). UL Listed, CSA Certified, ABS, MSHA Approved and RoHS 2011/65/EU Compliant.
- Provides better mechanical protection
- Offers shrink-fit electrical insulation
- Suitable for insulating electrical splices, connections and terminations
- Made of black cross-linked polyolefin
- Provides better mechanical protection
- Offers shrink-fit electrical insulation
- Suitable for insulating electrical splices, connections and terminations
- Made of black cross-linked polyolefin
- UPC
- 051135382349
- UNSPSC
- 39121723
- Country of Origin
- USA
- Color:
- Black
- Type:
- Heavy-Wall Cable Sleeve
- Color:
- Black
- Length:
- 48 in
- Shrink Ratio:
- 4 to 1
- Type:
- Heavy-Wall Cable Sleeve

46-310
$1.07 /ea
IDEAL, Heat Shrinkable Tube, Thermo-Shrink®, Thin-Wall, Shrink Ratio: 2:1, Outside Diameter: 1/8 IN, Thickness: 017 IN, Length: 6 IN, Volume Resistivity: 1014 OHM CM For ASTM D 876 Test Method, Dielectric Strength: 20 KV/MM For ASTM D 150 Test Method, Continuous Operating Temperature: -55 To 125 DEG C, Minimum Shrink Temperature: 70 DEG C, Heat Shock: No cracking For UL 224(250 DEG C /4 hours), Cable Range: 24 - 20 AWG, Nominal Recoveredi.d. (max.): 063 IN, Expanded I.d. (min.): 0.146, Elongation At Break: 600 PCT For ASTM D 638 Test Method, Elongation Of Break After Aging: 350 PCT For UL 224 Test Method, Cold Bend Test (-55°c/4 Hours): No Cracking For UL 224 Test Method, Copper Corrosion: Pass For UL 224 Test Method, Chemical Resistance: Pass For UL 224 Test Method, Longitudinal Shrinkage: 0 Plus Or Minus 5 PCT For UL 224 Test Method, Eccentricity: 30 PCT For UL 224 Test Method, Normal Size: 1/8 IN, Package: Bag
Attributed Data | Included |
---|---|
Dielectric Strength | 20 KV/MM For ASTM D 150 Test Method Yes |
Heat Shock | No cracking For UL 224(250 DEG C /4 hours) Yes |
Shrink Ratio | 2:1 Yes |
Standard | C/US RU Listed,RoHS Yes |
Sub Brand | Thermo-Shrink® Yes |
Type | Thin-Wall Yes |
Volume Resistivity | 1014 OHM CM For ASTM D 876 Test Method Yes |

46-313
$1.25 /ea
IDEAL, Heat Shrinkable Tube, Thermo-Shrink®, Thin-Wall, Shrink Ratio: 2:1, Outside Diameter: 0.187 IN, Thickness: 020 IN, Length: 6 IN, Volume Resistivity: 1014 OHM CM For ASTM D 876 Test Method, Dielectric Strength: 20 KV/MM For ASTM D 150 Test Method, Continuous Operating Temperature: -55 To 125 DEG C, Minimum Shrink Temperature: 70 DEG C, Heat Shock: No cracking For UL 224(250 DEG C /4 hours), Cable Range: 20 - 14 AWG, Nominal Recoveredi.d. (max.): 094 IN, Expanded I.d. (min.): 0.205, Elongation At Break: 600 PCT For ASTM D 638 Test Method, Elongation Of Break After Aging: 350 PCT For UL 224 Test Method, Cold Bend Test (-55°c/4 Hours): No Cracking For UL 224 Test Method, Copper Corrosion: Pass For UL 224 Test Method, Chemical Resistance: Pass For UL 224 Test Method, Longitudinal Shrinkage: 0 Plus Or Minus 5 PCT For UL 224 Test Method, Eccentricity: 30 PCT For UL 224 Test Method, Normal Size: 3/16 IN, Package: Bag
Attributed Data | Included |
---|---|
Dielectric Strength | 20 KV/MM For ASTM D 150 Test Method Yes |
Heat Shock | No cracking For UL 224(250 DEG C /4 hours) Yes |
Shrink Ratio | 2:1 Yes |
Standard | C/US RU Listed,RoHS Yes |
Sub Brand | Thermo-Shrink® Yes |
Type | Thin-Wall Yes |
Volume Resistivity | 1014 OHM CM For ASTM D 876 Test Method Yes |

46-316
$1.28 /ea
IDEAL, Heat Shrinkable Tube, Thermo-Shrink®, Thin-Wall, Shrink Ratio: 2:1, Outside Diameter: 0.250 IN, Thickness: 022 IN, Length: 6 IN, Dielectric Strength: 20 KV/MM For ASTM D 150 Test Method, Volume Resistivity: 1014 OHM CM For ASTM D 876 Test Method, Continuous Operating Temperature: -55 To 125 DEG C, Minimum Shrink Temperature: 70 DEG C, Heat Shock: No cracking For UL 224(250 DEG C /4 hours), Cable Range: 14 - 8 AWG, Nominal Recoveredi.d. (max.): 022 IN, Expanded I.d. (min.): 0.268, Elongation At Break: 600 PCT For ASTM D 638 Test Method, Elongation Of Break After Aging: 350 PCT For UL 224 Test Method, Cold Bend Test (-55°c/4 Hours): No Cracking For UL 224 Test Method, Copper Corrosion: Pass For UL 224 Test Method, Chemical Resistance: Pass For UL 224 Test Method, Longitudinal Shrinkage: 0 Plus Or Minus 5 PCT For UL 224 Test Method, Eccentricity: 30 PCT For UL 224 Test Method, Normal Size: 1/4 IN, Package: Bag
Attributed Data | Included |
---|---|
Dielectric Strength | 20 KV/MM For ASTM D 150 Test Method Yes |
Heat Shock | No cracking For UL 224(250 DEG C /4 hours) Yes |
Shrink Ratio | 2:1 Yes |
Standard | C/US RU Listed,RoHS Yes |
Sub Brand | Thermo-Shrink® Yes |
Type | Thin-Wall Yes |
Volume Resistivity | 1014 OHM CM For ASTM D 876 Test Method Yes |
Product Image | |||
---|---|---|---|
46-310
IDEAL, Heat Shrinkable Tube, Thermo-Shrink®, Thin-Wall, Shrink Ratio: 2:1, Outside Diameter: 1/8 IN, Thickness: 017 IN, Length: 6 IN, Volume Resistivity: 1014 OHM CM For ASTM D 876 Test Method, Dielectric Strength: 20 KV/MM For ASTM D 150 Test Method...
$1.07 / EA
|
46-313
IDEAL, Heat Shrinkable Tube, Thermo-Shrink®, Thin-Wall, Shrink Ratio: 2:1, Outside Diameter: 0.187 IN, Thickness: 020 IN, Length: 6 IN, Volume Resistivity: 1014 OHM CM For ASTM D 876 Test Method, Dielectric Strength: 20 KV/MM For ASTM D 150 Test Meth...
$1.25 / EA
|
46-316
IDEAL, Heat Shrinkable Tube, Thermo-Shrink®, Thin-Wall, Shrink Ratio: 2:1, Outside Diameter: 0.250 IN, Thickness: 022 IN, Length: 6 IN, Dielectric Strength: 20 KV/MM For ASTM D 150 Test Method, Volume Resistivity: 1014 OHM CM For ASTM D 876 Test Meth...
$1.28 / EA
|
|
Attributed Data | |||
Continuous Operating Temperature | -55 To 125 DEG C -55 To 125 DEG C | ||
Dielectric Strength | 20 KV/MM For ASTM D 150 Test Method 20 KV/MM For ASTM D 150 Test Method | ||
Heat Shock | No cracking For UL 224(250 DEG C /4 hours) No cracking For UL 224(250 DEG C /4 hours) | ||
Length | 6 in 6 in | ||
Minimum Shrink Temperature | 70 DEG C 70 DEG C | ||
Outside Diameter | 0.25 in 0.25 in | 0.125 in 0.125 in | 0.187 in 0.187 in |
Shrink Ratio | 2:1 2:1 | ||
Standard | C/US RU Listed,RoHS C/US RU Listed,RoHS | ||
Sub Brand | Thermo-Shrink® Thermo-Shrink® | ||
Thickness | 017 IN 017 IN | 020 IN 020 IN | 022 IN 022 IN |
Type | Thin-Wall Thin-Wall | ||
Volume Resistivity | 1014 OHM CM For ASTM D 876 Test Method 1014 OHM CM For ASTM D 876 Test Method | ||
Add a product to the cart | Show more details | Show more details | Show more details |