SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA63 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 250A 3-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU560 TRIP UNIT LCD LSIG. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 5.4 x 9.8 x 5.4.

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3VA6325-6JQ31-0AA0

$6,664.37 / EA

manufacturer discounts
learn about discounts

  • $5,974.96 for $1,500.00+
  • $5,745.15 for $2,500.00+
  • $5,515.34 for $3,500.00+

In stock (0)
Lead time: over 7 days
may be longer on small orders

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA63 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 250A 3-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU560 TRIP UNIT LCD LSIG. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 5.4 x 9.8 x 5.4.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA63 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 250A 3-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU560 TRIP UNIT LCD LSIG. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 5.4 x 9.8 x 5.4.

150

UPC
804766314308
UNSPSC
39121601
Country of Origin
CZ
Number Of Poles:
3
Type:
3VA6
Voltage Rating:
480 V
Connection:
punched copper bar without any lug
Current Rating:
250 A
Diken-export / tripping characteristics / Upper tolerance band:
AK_3VA6_3_250A_ETU5u8_MuHuCuL_oT
Frame:
400A
Height:
248
Interrupt Rating:
WITH 65kA INTERRUPTION RATING
Length:
5.43
N-Leiter Schutz / einstellbar:
Yes
N-Leiterschutz N / Einstellparameter Strom InN / Einheit der Werteliste:
Unit
N-Leiterschutz N / Einstellparameter Strom InN / Format der Werteliste:
xIn
N-leiter-schutz / Ein-/Ausschaltbar:
Yes
Number Of Poles:
3
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor:
s
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor of grading:
Settingtable
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Grading:
0.05-0.8;0.01
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / Factor:
s
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / Factor of grading:
Settingtable
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / Grading:
0.05-0.8;0.01
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor:
xIn
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor of grading:
Unit
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Grading:
0.2-1;0
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor:
xIn
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor of grading:
Unit
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Grading:
0.2-1;0
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor:
xIn
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Grading:
1.5-12;0
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Grading:
0.05-0.5;0.01
Setting range / ground fault function G / lg function selectable:
Yes
Standard:
UL
Sub Brand:
3VA
Trip Type:
ETU560 LSIG LCD
Type:
3VA6
Voltage Rating:
480 V
Width:
138
i-trip unit / can be switched ON/OFF:
No
version / Overcurrent release / Adjustability / Short-circuit function, instantaneous I:
Yes
Compare With Similar Items
BREAKER-CIRCUIT (50453750)

45375G

$48.43 /ea

BREAKER-CIRCUIT (50453750)

SWITCH,CIRCUIT BREAKER (52040980)

10712-GRNL

$80.56 /ea

SWITCH,CIRCUIT BREAKER (52040980)

SWITCH,CIRCUIT BREAKER (120V 16A S-P) (91861527)

86152-GRNL

$201.84 /ea

SWITCH,CIRCUIT BREAKER (120V 16A S-P) (91861527)

ADDED TO CART