$6,468.02 / EA
manufacturer discounts
learn about discounts
- $5,798.91 for $1,500.00+
- $5,575.88 for $2,500.00+
- $5,352.84 for $3,500.00+
In stock (0)
Lead time: over 7 days
may be longer on small orders
CIRCUIT BREAKER VL 150X UL, TYPE CG (CAT NO. NCX3B050) NON-INTERCHANGEABLE FRAME W/APPROVAL CIRCUIT BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING65KA/480V (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI FUNCTION TU=40DEGR CELSIUS IN= ( <) 50A RATED CURRENT II=600A SHORT-CIRCUIT PROT. IR=50A OVERCURRENT RELEASE FOR SYSTEM PROTECTION W/O CONNECTION ACCESSORIES WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT BREAKER VL 150X UL, TYPE CG (CAT NO. NCX3B050) NON-INTERCHANGEABLE FRAME W/APPROVAL CIRCUIT BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING65KA/480V (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI FUNCTION TU=40DEGR CELSIUS IN= ( <) 50A RATED CURRENT II=600A SHORT-CIRCUIT PROT. IR=50A OVERCURRENT RELEASE FOR SYSTEM PROTECTION W/O CONNECTION ACCESSORIES WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
150
- UPC
- 662643160208
- UNSPSC
- 39121601
- Country of Origin
- DE
- Material:
- MOLDED CASE CIRCUIT BREAKER
- Number Of Poles:
- 3
- Type:
- CG
- Voltage Rating:
- 690 V
- Connection:
- withoutconnectionaccessoires
- Current Rating:
- 50 A
- Current limitation characteristic, no. / Let-through energy / 240 V:
- DE_VL160x_50_TM_240
- Current limitation characteristic, no. / Let-through energy / 415 V:
- DE_VL160x_50_TM_415
- Current limitation characteristic, no. / Let-through energy / 440 V:
- DE_VL160x_50_TM_440
- Current limitation characteristic, no. / Let-through energy / 500 V:
- DE_VL160x_50_TM_500
- Current limitation characteristic, no. / Let-through energy / 690 V:
- DE_VL160x_50_TM_690
- Electrical endurance (switching cycles) / typical:
- 10000
- Frame:
- 3VL1UL
- Frequency Rating:
- 50/60 Hz
- Height:
- 157.5 in
- Interrupt Rating:
- 65 kA
- Length:
- 104.5 in
- Manufacturer:
- SiemensAG
- Material:
- MOLDED CASE CIRCUIT BREAKER
- Maximum short-circuit current breaking capacity (Icu) / at 415 V / rated value:
- 70 kA
- Maximum short-circuit current breaking capacity (Icu) / at 600 V / acc. to NEMA / Rated value:
- 10 kA
- Number Of Poles:
- 3
- Product component / Trip indicator:
- No
- Product extension / optional / motor drive:
- Yes
- Rated short-circuit making capacity Icm / 240 V:
- 254
- Rated short-circuit making capacity Icm / 415 V:
- 177.8
- Rated short-circuit making capacity Icm / 690 V:
- 25.4
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / max:
- 0.5
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / minimum:
- 0.1
- Standard:
- ULhighswitchingcapacity(H),non-interchangeable
- Sub Brand:
- VL
- Trip Type:
- TM
- Type:
- CG
- Type of the driving mechanism / motor drive:
- No
- Unit type:
- Type1
- Voltage Rating:
- 690 V
- Width:
- 106.5 in
45375G
$48.43 /ea
BREAKER-CIRCUIT (50453750)
10712-GRNL
$80.56 /ea
SWITCH,CIRCUIT BREAKER (52040980)
86152-GRNL
$201.84 /ea
SWITCH,CIRCUIT BREAKER (120V 16A S-P) (91861527)
| Product Image | |||
|---|---|---|---|
|
45375G
BREAKER-CIRCUIT (50453750)
$48.43 / EA
|
10712-GRNL
SWITCH,CIRCUIT BREAKER (52040980)
$80.56 / EA
|
86152-GRNL
SWITCH,CIRCUIT BREAKER (120V 16A S-P) (91861527)
$201.84 / EA
|
|
| Attributed Data | |||