Enclosed soft starter, Controller 3RW44271BC34, H2 Std. duty current rating 82A, Control voltage 115 AC, Non-combination type, Enclosure NEMA type 1, Indoor general purpose use
Enclosed soft starter, Controller 3RW44271BC34, H2 Std. duty current rating 82A, Control voltage 115 AC, Non-combination type, Enclosure NEMA type 1, Indoor general purpose use
150
- UPC
- 783087824232
- Configuration of control input / 1:
- FactorysetasSTARTMOTOR
- Configuration of relay output / 1:
- FactorysetasON-TIMEMOTOR
- Configuration of relay output / 2:
- programmable
- Configuration of relay output / 3:
- programmable
- Configuration of relay output / 4:
- FactorysetasGROUPERROR
- Consumed active power [hp] / at severe duty / maximum:
- 60 hp
- Consumed active power [hp] / at standard duty / maximum:
- 60 hp
- Control supply voltage / at AC / at 50 Hz / Rated value / minimum:
- 115 V
- Control supply voltage / at AC / at 60 Hz / Rated value / maximum:
- 115 V
- Design of power semiconductors (thyristors) / for soft starter control:
- 3controlledphases
- Design of the fuse link / for short-circuit protection of the main circuit / required:
- 10kA@600V(ClassHorK);100kA@600V(ClassRorJ)
- Design of the housing:
- Indoorgeneralpurposeuse
- Design of the short-circuit trip:
- Thermalmagneticcircuitbreaker
- Display version:
- Graphicdisplay
- Manufacturer's article number / of soft starter:
- 3RW44271BC34
- Material / of the conductor / for load-side outgoing feeder:
- CU
- Material / of the conductor / for supply:
- CU
- Mounting type:
- Surfacemountingandinstallation
- Operating condition / for severe duty:
- Class20severeduty(350%ofmotorFLAfor20seconds)
- Operating condition / for standard duty:
- Class10standardduty(350%ofmotorFLAfor10seconds)
- Operating current / at severe duty / rated value:
- 82 A
- Operating current / at standard duty / rated value:
- 82 A
- Operating voltage / at AC-3 / Rated value / maximum:
- 460 V
- Operating voltage / for main current circuit / at AC / at 60 Hz / maximum:
- 460 V
- Product function:
- Enclosedsoftstarter
- Reset function:
- Manualandautomatic
- Trip CLASS:
- Class5/10/15/20/30
- Type of communication / optional:
- WithoptionalProfibusorProfinet
- Type of connectable conductor cross-section / for AWG conductors / for line-side / single or multi-stranded:
- 2/0...14AWG
- Type of connectable conductor cross-section / for AWG conductors / for load-side outgoing feeder / single or multi-stranded:
- 10...2/0AWG(frontonly)or10...2/0AWG(backonly)or2x(10...1/0AWG)(bothfront&back)
- Type of cooling:
- None
- Type of electrical connection / for auxiliary and control current circuit:
- screw-typeterminals
- Type of electrical connection / for load-side outgoing feeder:
- Boxlug
- Type of electrical connection / for supply voltage infeed -> line-side:
- Screw-typeterminals
- Type of voltage / of the control supply voltage:
- AC
- country of origin:
- USA
- mounting position:
- Vertical