Call Us Today: (800) 462-7733
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA55 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 600A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). TM230 TRIP UNIT WITH FIXED Ir ADJUSTABLE Ii. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H xD) IN 11.1 x 12.5 x 5.8.

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3VA5560-5EC42-0AA0

$5,678.84 / EA

manufacturer discounts
learn about discounts

  • $5,091.37 for $1,500.00+
  • $4,895.55 for $2,500.00+
  • $4,699.73 for $3,500.00+
Available to order

Local stock: 0
Lead time: over 7 working days

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA55 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 600A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). TM230 TRIP UNIT WITH FIXED Ir ADJUSTABLE Ii. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H xD) IN 11.1 x 12.5 x 5.8.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA55 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 600A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). TM230 TRIP UNIT WITH FIXED Ir ADJUSTABLE Ii. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H xD) IN 11.1 x 12.5 x 5.8.

150

UPC
804766978272
Number Of Poles:
4
Arrangement of electrical connectors / for main current circuit:
Frontconnection
Continuous current / rated value / maximum:
800A
Design of short-circuit protection:
ForswitchingpowervaluesinDCnetworks,seethe3VAmoldedcasecircuitbreakerdevicemanual;linktobefoundunderService&Supportinthelastchapter
Design of the operating mechanism:
togglehandle
Ground fault monitoring version:
Without
Height:
328 mm
Insulation voltage / rated value:
1000 V
Maximum short-circuit current breaking capacity (Icu) / at 690 V / rated value:
25
Number Of Poles:
4
Operating voltage / at AC / at 50/60 Hz / rated value:
600 V
Operating voltage / at DC / rated value:
600
Operational short-circuit current breaking capacity (Ics) / at 415 V / rated value:
55kA
Operational short-circuit current breaking capacity (Ics) / at 690 V / rated value:
19
Overcurrent release / Protective functions:
LI
Product component / display:
No
Product feature / for neutral conductors / upgradeable/retrofittable / Short-circuit and overload proof:
No
Product function / Intrinsic device protection:
Yes
Product function / communication function:
No
Product function / other measurement function:
No
Protective function of the overcurrent release:
LI
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor:
s
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor of grading:
Fixed
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Grading:
1
Setting range / Overload function L / I**4tI**2t can be changed over:
No
Setting range / Overload function L / IR can be switched on:
Yes
Setting range / Overload function L / Setting current IR / Factor:
xIn
Setting range / Overload function L / Setting current IR / Factor of grading:
Unit
Setting range / Overload function L / Setting current IR / Grading:
1
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor:
xIn
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor of grading:
Unit
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / can be switched on/off:
No
Short-circuit current making capacity (Icm) / at 415 V / rated value:
121.0kA
Switching capacity class of the circuit breaker:
M
Type of the driving mechanism / motor drive:
No
Width:
280 mm
circuit-breaker / Design:
3VA5
version / Overcurrent release / Adjustability / Overload function L:
Yes

Recently Viewed

  • placeholder image

    3VA5560-5EC42-0AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA55 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 600...
    See more details
  • placeholder image

    3VA1150-3GE46-0AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA IEC MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETICTRIP UNIT. 3VA11 FRAME WITH LOW (CLASS N) BREAKING CAPACITY. 50A 4-POLE...
    See more details
  • placeholder image

    3602-14 BLK-BK

    GOLDEN LIGHTING
    Unfortunately, we do not have a description available for 3602-14 BLK-BK. Please call (800) 462-77...
    See more details
  • placeholder image

    LV231-L7-65K-ABZ

    DABMAR LIGHTING INC.
    Unfortunately, we do not have a description available for LV231-L7-65K-ABZ. Please call (800) 462-...
    See more details
  • placeholder image

    3VA6115-7JT36-0AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH VERY HIGH (CLASS C) BREAKING CAPACITY. 150A 3-POLE...
    See more details

ADDED TO CART