Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more
information.
$14,422.34 / EA
manufacturer discounts
learn about discounts
- $12,930.37 for $1,500.00+
- $12,433.05 for $2,500.00+
- $11,935.73 for $3,500.00+
Local stock: 0
Lead time:
over 7 working days
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA63 FRAME WITH EXTREMELY HIGH (CLASS L) BREAKING CAPACITY. 400A 4-POLE (50KAIC AT 600V) (150KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 7.2 x 9.8 x 5.4.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA63 FRAME WITH EXTREMELY HIGH (CLASS L) BREAKING CAPACITY. 400A 4-POLE (50KAIC AT 600V) (150KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 7.2 x 9.8 x 5.4.
150
- UPC
- 804766315077
- UNSPSC
- 39121601
- Country of Origin
- CZ
- Number Of Poles:
- 4
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Connection:
- punched copper bar without any lug
- Current Rating:
- 400A
- Depth:
- 110
- Design of the operating mechanism:
- togglehandle
- Design of the overcurrent release:
- ETU856
- Design of the product:
- Systemprotection
- Frame:
- 400A
- Height:
- 248
- Interrupt Rating:
- WITH 150kA INTERRUPTION RATING
- Length:
- 7.24
- Number Of Poles:
- 4
- Power loss [W] / maximum:
- 70
- Product component / adjusting knob:
- No
- Product designation:
- Molded-casecircuitbreaker
- Product designation / according to UL file:
- LJAE
- Product function / communication function:
- Yes
- Product function / other measurement function:
- Yes
- Protective function of the overcurrent release:
- LSI
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / max:
- 0.8
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / minimum:
- 0.05
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / max:
- 0.8
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / minimum:
- 0.05
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / minimum:
- 0.2
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / minimum:
- 0.2
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / minimum:
- 1.5
- Short-circuit current making capacity (Icm) / at 690 V / rated value:
- 7.50kA
- Simaris relevant:
- -
- Standard:
- UL
- Sub Brand:
- 3VA
- Suitability for use:
- systemprotection
- Trip Type:
- ETU856 LSI(G) LCD
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Width:
- 184
- circuit-breaker / Design:
- 3VA6
- product brand name:
- SENTRON