Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more
information.
$15,851.05 / EA
manufacturer discounts
learn about discounts
- $14,211.29 for $1,500.00+
- $13,664.70 for $2,500.00+
- $13,118.11 for $3,500.00+
Local stock: 0
Lead time:
over 7 working days
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA64 FRAME WITH VERY HIGH (CLASS C) BREAKING CAPACITY. 400A 4-POLE (35KAIC AT 600V) (100KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING. SPECIAL FEATURES WITHOUT LUGS 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 7.2 x9.8 x 5.4.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA64 FRAME WITH VERY HIGH (CLASS C) BREAKING CAPACITY. 400A 4-POLE (35KAIC AT 600V) (100KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING. SPECIAL FEATURES WITHOUT LUGS 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 7.2 x9.8 x 5.4.
150
- UPC
- 804766317842
- UNSPSC
- 39121601
- Country of Origin
- CZ
- Number Of Poles:
- 4
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Connection:
- punched copper bar without any lug
- Current Rating:
- 400A
- Diken-export / tripping characteristics / Upper tolerance band:
- AK_3VA6_4_400A_ETU5u8_MuHuCuL_oT
- Frame:
- 600A
- Height:
- 248
- Interrupt Rating:
- WITH 100kA INTERRUPTION RATING
- Length:
- 7.24
- N-Leiter Schutz / einstellbar:
- Yes
- N-Leiterschutz N / Einstellparameter Strom InN / Einheit der Werteliste:
- Unit
- N-Leiterschutz N / Einstellparameter Strom InN / Format der Werteliste:
- xIn
- N-Leiterschutz N / Einstellparameter Strom InN / Werteliste:
- 0.2-1.5;0
- N-leiter-schutz / Ein-/Ausschaltbar:
- Yes
- Number Of Poles:
- 4
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor:
- s
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor of grading:
- Settingtable
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Grading:
- 0.05-0.8;0.01
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / Factor:
- s
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / Factor of grading:
- Settingtable
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / Grading:
- 0.05-0.8;0.01
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor:
- xIn
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor of grading:
- Unit
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Grading:
- 0.2-1;0
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor:
- xIn
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor of grading:
- Unit
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Grading:
- 0.2-1;0
- Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Grading:
- 0.05-0.5;0.01
- Setting range / ground fault function G / lg function selectable:
- Yes
- Standard:
- UL
- Sub Brand:
- 3VA
- Trip Type:
- ETU856 LSI(G) LCD
- Tripping characteristics / Lower tolerance band:
- AK_3VA6_4_400A_ETU5u8_MuHuCuL_uT
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Width:
- 184
- i-trip unit / can be switched ON/OFF:
- No