SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA64 FRAME WITH EXTREMELY HIGH (CLASS L) BREAKING CAPACITY. 600A 3-POLE (50KAIC AT 600V) (150KAIC AT 480V). ETU560 TRIP UNIT LCD LSIG. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 5.4 x 9.8 x 5.4.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA64 FRAME WITH EXTREMELY HIGH (CLASS L) BREAKING CAPACITY. 600A 3-POLE (50KAIC AT 600V) (150KAIC AT 480V). ETU560 TRIP UNIT LCD LSIG. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 5.4 x 9.8 x 5.4.
150
- UPC
- 804766315411
- UNSPSC
- 39121601
- Country of Origin
- CZ
- Number Of Poles:
- 3
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Adjustable delay time / for G-tripping / with I2t characteristic / Full-scale value:
- 0.80s
- Adjustable delay time / for G-tripping / with I2t characteristic / initial value:
- 0.05s
- Adjustable delay time / of S-trip / with standard characteristic / initial value:
- 0.05s
- Adjustable pick-up value current / for G-tripping / with standard characteristic / Full-scale value:
- 600.00A
- Adjustable pick-up value current / for G-tripping / with standard characteristic / initial value:
- 120.00A
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / Full-scale value:
- 5400
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / initial value:
- 900
- Adjustable pick-up value current / of the current-dependent overload release / Full-scale value:
- 600
- Adjustable pick-up value current / of the current-dependent overload release / initial value:
- 240
- Adjustable pick-up value current / of the short-time delayed short-circuit release / Full-scale value:
- 5400.00A
- Adjustable pick-up value current / of the short-time delayed short-circuit release / initial value:
- 360.00A
- Connection:
- punched copper bar without any lug
- Current Rating:
- 600A
- Frame:
- 600A
- Ground fault monitoring version:
- SummationcurrentformationL-conductor
- Height:
- 248
- Insulation voltage / rated value:
- 600
- Interrupt Rating:
- WITH 150kA INTERRUPTION RATING
- Length:
- 5.43
- Maximum short-circuit current breaking capacity (Icu) / at 240 V / rated value:
- 200
- Maximum short-circuit current breaking capacity (Icu) / at 415 V / rated value:
- 150
- Number Of Poles:
- 3
- Operating current / at 65 °C / rated value:
- 480
- Operating voltage / at AC / at 50/60 Hz / rated value:
- 600
- Operational short-circuit current breaking capacity (Ics) / at 240 V / rated value:
- 200kA
- Operational short-circuit current breaking capacity (Ics) / at 415 V / rated value:
- 150kA
- Operational short-circuit current breaking capacity (Ics) / at 690 V / rated value:
- 6
- Power loss [W] / for rated value of the current / at AC / in hot operating state / per pole:
- 50.33
- Product feature / for neutral conductors / upgradeable/retrofittable / Short-circuit and overload proof:
- Yes
- Standard:
- UL
- Sub Brand:
- 3VA
- Switching capacity class of the circuit breaker:
- L
- Trip Type:
- ETU560 LSIG LCD
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Width:
- 138