3M™ Cold Shrink QS-III 3/C Inline Armored or Non-Armored Cable Splices 5786A-MT, 5787A-MT and 5788A-MT are designed for splicing 3-conductor, armored and non-armored, shielded power cables. The kits are rated for use on 25/28 kV cables with conductor sizes from 1 AWG-1000 kcmil (50-500 mm²).

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

5787A-MT

Manufacturer
3M

$5,183.75 / EA

Available to order

Local stock: 0
Lead time: over 7 working days

3M™ Cold Shrink QS-III 3/C Inline Armored or Non-Armored Cable Splices 5786A-MT, 5787A-MT and 5788A-MT are designed for splicing 3-conductor, armored and non-armored, shielded power cables. The kits are rated for use on 25/28 kV cables with conductor sizes from 1 AWG-1000 kcmil (50-500 mm²).

3M™ Cold Shrink QS-III 3/C Inline Armored or Non-Armored Cable Splices 5786A-MT, 5787A-MT and 5788A-MT are designed for splicing 3-conductor, armored and non-armored, shielded power cables. The kits are rated for use on 25/28 kV cables with conductor sizes from 1 AWG-1000 kcmil (50-500 mm²).

The kits are designed to be used with 3M™ Scotchlok™ Connectors 10000 and 20000 Series or other UL l...150

The kits are designed to be used with 3M™ Scotchlok™ Connectors 10000 and 20000 Series or other UL listed inline compression connectors that fit within the dimension limits listed in the connector dimensional requirements on the data sheet. The splice utilizes several technologies to accommodate the various functions of a 3/C shielded power cable: 3M™ Cold Shrink QS-III Splice Bodies, Scotch® Tapes for moisture sealing, Constant Force Springs for connecting ground braid jumpers and Armorcast for replacing the cable armor and/or jacket. The completed splice is designed for use in cable trays, weather exposed or direct burial locations. Meets the requirements of IEEE 404.Connectors are not included in the kit and must be ordered separately.Note: When making a trifurcating splice, the 3M™ Cold Shrink MT-C or MT-E Trifurcating Accessory Kit must be used along with the splice kit.Note: Cable sizes shown below are for standard insulation thickness. Final determining factor is cable insulation O.D.

  • Splices shielded cables
  • Silicon rubber-splice body provides good high- or low-temperature performance and Armorcast™ jacket offers mechanical protection
  • Suitable for use with 10000 and 20000 Series connectors or other UL Listed inline compression connectors
  • Solderless ground braid offers constant force spring connection
  • Splices shielded cables
  • Silicon rubber-splice body provides good high- or low-temperature performance and Armorcast™ jacket offers mechanical protection
  • Suitable for use with 10000 and 20000 Series connectors or other UL Listed inline compression connectors
  • Solderless ground braid offers constant force spring connection
UPC
054007434214
UNSPSC
26121649
Country of Origin
USA
Type:
Inline; Trifurcating
Voltage Rating:
25,000/28,000 V
Cable Type:
Longitudinally Corrugated (LC); Tape Shield; UniShield(R); Wire Shield
Conductor Size:
250 kcmil; 350 kcmil; 500 kcmil; 750 kcmil
Number of Conductors:
3
Product Technology:
Cold Shrink
Type:
Inline; Trifurcating
Voltage Rating:
25,000/28,000 V

Recently Viewed

  • placeholder image

    5787A-MT

    3M
    3M™ Cold Shrink QS-III 3/C Inline Armored or Non-Armored Cable Splices 5786A-MT, 5787A-MT and 5788A-MT are designed for splicing 3-conductor, armored...
    See more details
  • placeholder image

    TXV12114Z

    NSI INDUSTRIES
    Heavy Duty Drill Screw, Steel material, 12 in. Size, 1-1/4 in. length, 5/16 in. head width, Hex Washer head, 100 per pack, Hex drive type, #5 drill si...
    See more details
  • placeholder image

    US2:17DUE82WF10

    SIEMENS INDUSTRY, INC.
    Non-reversing motor starter, Size 1, H2 Solid-state overload relay, OLR amp range 10-40A, 110V 50Hz / 120V 60Hz coil, Combination type, 30A fusible di...
    See more details
  • placeholder image

    139656-LED-STND-07-89

    HUBBARDTON FORGE
    Unfortunately, we do not have a description available for 139656-LED-STND-07-89. Please call (800)...
    See more details
  • placeholder image

    ML22-12793W-HBMB-FS

    JESCO LIGHTING GROUP
    ML2/2LT - 120V/2700K/93 CRI/WIDE BEAM - HSG BLACK/MOD BLACK - FLANGE SILVER
    See more details

ADDED TO CART