$69.13 / EA
In stock (0)
Lead time: over 7 days
may be longer on small orders
3M™ Heat Shrink End Cap SKE provides mechanical and environmental protection as well as sealing to cable ends. The semi rigid, flame retardant polyolefin construction makes the end cap suitable for heavy duty applications. The adhesive lining forms a permanent, flexible and water resistant barrier.
3M™ Heat Shrink End Cap SKE provides mechanical and environmental protection as well as sealing to cable ends. The semi rigid, flame retardant polyolefin construction makes the end cap suitable for heavy duty applications. The adhesive lining forms a permanent, flexible and water resistant barrier.
3M™ Heat Shrink Heavy Duty End Cap SKE has a flexible adhesive lining and is suitable for use on a v...150
3M™ Heat Shrink Heavy Duty End Cap SKE has a flexible adhesive lining and is suitable for use on a variety of rubbers, plastics and metals. It withstands a wide temperature range of 67 to 230 degrees F ( 55 to 110 degrees C). RoHS 2011/65/EU Compliant.
- Offers mechanical and environmental protection to cable ends
- Adhesive lining offers flexible, water-resistant barrier
- Suitable for heavy-duty applications
- Comes in black color
- Offers mechanical and environmental protection to cable ends
- Adhesive lining offers flexible, water-resistant barrier
- Suitable for heavy-duty applications
- Comes in black color
- UPC
- 051138481568
- UNSPSC
- 39121723
- Country of Origin
- CHN
- Color:
- Black
- Type:
- Heat Shrink Heavy-Duty End Cap
- Color:
- Black
- Length:
- 0.63 in
- Type:
- Heat Shrink Heavy-Duty End Cap

46-310
$1.07 /ea
IDEAL, Heat Shrinkable Tube, Thermo-Shrink®, Thin-Wall, Shrink Ratio: 2:1, Outside Diameter: 1/8 IN, Thickness: 017 IN, Length: 6 IN, Volume Resistivity: 1014 OHM CM For ASTM D 876 Test Method, Dielectric Strength: 20 KV/MM For ASTM D 150 Test Method, Continuous Operating Temperature: -55 To 125 DEG C, Minimum Shrink Temperature: 70 DEG C, Heat Shock: No cracking For UL 224(250 DEG C /4 hours), Cable Range: 24 - 20 AWG, Nominal Recoveredi.d. (max.): 063 IN, Expanded I.d. (min.): 0.146, Elongation At Break: 600 PCT For ASTM D 638 Test Method, Elongation Of Break After Aging: 350 PCT For UL 224 Test Method, Cold Bend Test (-55°c/4 Hours): No Cracking For UL 224 Test Method, Copper Corrosion: Pass For UL 224 Test Method, Chemical Resistance: Pass For UL 224 Test Method, Longitudinal Shrinkage: 0 Plus Or Minus 5 PCT For UL 224 Test Method, Eccentricity: 30 PCT For UL 224 Test Method, Normal Size: 1/8 IN, Package: Bag
Attributed Data | Included |
---|---|
Dielectric Strength | 20 KV/MM For ASTM D 150 Test Method Yes |
Heat Shock | No cracking For UL 224(250 DEG C /4 hours) Yes |
Shrink Ratio | 2:1 Yes |
Standard | C/US RU Listed,RoHS Yes |
Sub Brand | Thermo-Shrink® Yes |
Type | Thin-Wall Yes |
Volume Resistivity | 1014 OHM CM For ASTM D 876 Test Method Yes |

46-313
$1.25 /ea
IDEAL, Heat Shrinkable Tube, Thermo-Shrink®, Thin-Wall, Shrink Ratio: 2:1, Outside Diameter: 0.187 IN, Thickness: 020 IN, Length: 6 IN, Volume Resistivity: 1014 OHM CM For ASTM D 876 Test Method, Dielectric Strength: 20 KV/MM For ASTM D 150 Test Method, Continuous Operating Temperature: -55 To 125 DEG C, Minimum Shrink Temperature: 70 DEG C, Heat Shock: No cracking For UL 224(250 DEG C /4 hours), Cable Range: 20 - 14 AWG, Nominal Recoveredi.d. (max.): 094 IN, Expanded I.d. (min.): 0.205, Elongation At Break: 600 PCT For ASTM D 638 Test Method, Elongation Of Break After Aging: 350 PCT For UL 224 Test Method, Cold Bend Test (-55°c/4 Hours): No Cracking For UL 224 Test Method, Copper Corrosion: Pass For UL 224 Test Method, Chemical Resistance: Pass For UL 224 Test Method, Longitudinal Shrinkage: 0 Plus Or Minus 5 PCT For UL 224 Test Method, Eccentricity: 30 PCT For UL 224 Test Method, Normal Size: 3/16 IN, Package: Bag
Attributed Data | Included |
---|---|
Dielectric Strength | 20 KV/MM For ASTM D 150 Test Method Yes |
Heat Shock | No cracking For UL 224(250 DEG C /4 hours) Yes |
Shrink Ratio | 2:1 Yes |
Standard | C/US RU Listed,RoHS Yes |
Sub Brand | Thermo-Shrink® Yes |
Type | Thin-Wall Yes |
Volume Resistivity | 1014 OHM CM For ASTM D 876 Test Method Yes |

46-316
$1.28 /ea
IDEAL, Heat Shrinkable Tube, Thermo-Shrink®, Thin-Wall, Shrink Ratio: 2:1, Outside Diameter: 0.250 IN, Thickness: 022 IN, Length: 6 IN, Dielectric Strength: 20 KV/MM For ASTM D 150 Test Method, Volume Resistivity: 1014 OHM CM For ASTM D 876 Test Method, Continuous Operating Temperature: -55 To 125 DEG C, Minimum Shrink Temperature: 70 DEG C, Heat Shock: No cracking For UL 224(250 DEG C /4 hours), Cable Range: 14 - 8 AWG, Nominal Recoveredi.d. (max.): 022 IN, Expanded I.d. (min.): 0.268, Elongation At Break: 600 PCT For ASTM D 638 Test Method, Elongation Of Break After Aging: 350 PCT For UL 224 Test Method, Cold Bend Test (-55°c/4 Hours): No Cracking For UL 224 Test Method, Copper Corrosion: Pass For UL 224 Test Method, Chemical Resistance: Pass For UL 224 Test Method, Longitudinal Shrinkage: 0 Plus Or Minus 5 PCT For UL 224 Test Method, Eccentricity: 30 PCT For UL 224 Test Method, Normal Size: 1/4 IN, Package: Bag
Attributed Data | Included |
---|---|
Dielectric Strength | 20 KV/MM For ASTM D 150 Test Method Yes |
Heat Shock | No cracking For UL 224(250 DEG C /4 hours) Yes |
Shrink Ratio | 2:1 Yes |
Standard | C/US RU Listed,RoHS Yes |
Sub Brand | Thermo-Shrink® Yes |
Type | Thin-Wall Yes |
Volume Resistivity | 1014 OHM CM For ASTM D 876 Test Method Yes |
Product Image | |||
---|---|---|---|
46-310
IDEAL, Heat Shrinkable Tube, Thermo-Shrink®, Thin-Wall, Shrink Ratio: 2:1, Outside Diameter: 1/8 IN, Thickness: 017 IN, Length: 6 IN, Volume Resistivity: 1014 OHM CM For ASTM D 876 Test Method, Dielectric Strength: 20 KV/MM For ASTM D 150 Test Method...
$1.07 / EA
|
46-313
IDEAL, Heat Shrinkable Tube, Thermo-Shrink®, Thin-Wall, Shrink Ratio: 2:1, Outside Diameter: 0.187 IN, Thickness: 020 IN, Length: 6 IN, Volume Resistivity: 1014 OHM CM For ASTM D 876 Test Method, Dielectric Strength: 20 KV/MM For ASTM D 150 Test Meth...
$1.25 / EA
|
46-316
IDEAL, Heat Shrinkable Tube, Thermo-Shrink®, Thin-Wall, Shrink Ratio: 2:1, Outside Diameter: 0.250 IN, Thickness: 022 IN, Length: 6 IN, Dielectric Strength: 20 KV/MM For ASTM D 150 Test Method, Volume Resistivity: 1014 OHM CM For ASTM D 876 Test Meth...
$1.28 / EA
|
|
Attributed Data | |||
Continuous Operating Temperature | -55 To 125 DEG C -55 To 125 DEG C | ||
Dielectric Strength | 20 KV/MM For ASTM D 150 Test Method 20 KV/MM For ASTM D 150 Test Method | ||
Heat Shock | No cracking For UL 224(250 DEG C /4 hours) No cracking For UL 224(250 DEG C /4 hours) | ||
Length | 6 in 6 in | ||
Minimum Shrink Temperature | 70 DEG C 70 DEG C | ||
Outside Diameter | 0.25 in 0.25 in | 0.125 in 0.125 in | 0.187 in 0.187 in |
Shrink Ratio | 2:1 2:1 | ||
Standard | C/US RU Listed,RoHS C/US RU Listed,RoHS | ||
Sub Brand | Thermo-Shrink® Thermo-Shrink® | ||
Thickness | 017 IN 017 IN | 020 IN 020 IN | 022 IN 022 IN |
Type | Thin-Wall Thin-Wall | ||
Volume Resistivity | 1014 OHM CM For ASTM D 876 Test Method 1014 OHM CM For ASTM D 876 Test Method | ||
Add a product to the cart | Show more details | Show more details | Show more details |