Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more
information.
$11,539.35 / EA
manufacturer discounts
learn about discounts
- $10,345.62 for $1,500.00+
- $9,947.71 for $2,500.00+
- $9,549.80 for $3,500.00+
In stock (0)
Lead time: over 7 days
may be longer on small orders
CIRCUIT-BREAKER VL 150 UL TYPE DG (CAT NO. HDK3B050) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER ACC. UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA@480V AND 18KA@600/347V (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI TU= 40 DEGR. CELSIUS IN=50A, RATED CURRENT II= 450...700A SHORT-CIRCUIT PROTECTION IR= 50A OVERCURRENT RELEASE F. PLANT PROTECTION W/O CONNECTION ACCESSORIES WITHOUT AUXILIARY RELEASE AUXILIARY/ALARM SWITCH KIT 2HS(1NO+1NC)+1AS(1NO)
CIRCUIT-BREAKER VL 150 UL TYPE DG (CAT NO. HDK3B050) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER ACC. UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA@480V AND 18KA@600/347V (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI TU= 40 DEGR. CELSIUS IN=50A, RATED CURRENT II= 450...700A SHORT-CIRCUIT PROTECTION IR= 50A OVERCURRENT RELEASE F. PLANT PROTECTION W/O CONNECTION ACCESSORIES WITHOUT AUXILIARY RELEASE AUXILIARY/ALARM SWITCH KIT 2HS(1NO+1NC)+1AS(1NO)
150
- UPC
- 887621125905
- UNSPSC
- 39121601
- Country of Origin
- DE
- Material:
- MOLDED CASE CIRCUIT BREAKER
- Number Of Poles:
- 3
- Type:
- DG
- Voltage Rating:
- 600Y V
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / Full-scale value:
- 700 A
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / initial value:
- 450 A
- Adjustable pick-up value current / of the current-dependent overload release / Full-scale value:
- 50 A
- Adjustable pick-up value current / of the current-dependent overload release / initial value:
- 50 A
- Ambient temperature / during operation / maximum:
- 70 °C
- Auxiliary Contacts:
- 1
- Auxiliary release:
- WITHOUTAUXILIARYRELEASE
- Connection:
- withoutconnectionaccessoires
- Current Rating:
- 50 A
- Derating temperature / for the rated value of the continuous current / acc. to UL 489:
- 40.0°C
- Diken-export / tripping characteristics / Upper tolerance band:
- AK_VL250_TM_I_u.txt
- Frame:
- DG
- Frequency Rating:
- 50/60 Hz
- Interrupt Rating:
- 18KA kA
- Material:
- MOLDED CASE CIRCUIT BREAKER
- Number Of Poles:
- 3
- Operating Temperature:
- 40DEGC °C
- Operating voltage / for main current circuit / at AC / at 50 Hz / acc. to UL 489 / maximum:
- 600.0V
- Operating voltage / for main current circuit / at AC / at 50 Hz / maximum:
- 690.0V
- Operating voltage / for main current circuit / at AC / at 60 Hz / acc. to UL 489 / maximum:
- 600.0V
- Operating voltage / for main current circuit / at AC / at 60 Hz / maximum:
- 690.0V
- Product component / Voltage trigger:
- No
- Product function / for neutral conductors / Short-circuit and overload proof:
- No
- Protection class IP:
- IP20
- Reference code / acc. to DIN 40719 extended according to IEC 204-2 / acc. to IEC 750:
- Q
- Standard:
- UL
- Sub Brand:
- VL
- Trip Type:
- THERMAL MAGNETIC TRIP UNIT
- Tripping characteristics / Lower tolerance band:
- AK_VL160x_TM_I_o.txt
- Type:
- DG
- Voltage Rating:
- 600Y V
45375G
$48.43 /ea
BREAKER-CIRCUIT (50453750)
10712-GRNL
$80.56 /ea
SWITCH,CIRCUIT BREAKER (52040980)
86152-GRNL
$201.84 /ea
SWITCH,CIRCUIT BREAKER (120V 16A S-P) (91861527)
| Product Image | |||
|---|---|---|---|
|
45375G
BREAKER-CIRCUIT (50453750)
$48.43 / EA
|
10712-GRNL
SWITCH,CIRCUIT BREAKER (52040980)
$80.56 / EA
|
86152-GRNL
SWITCH,CIRCUIT BREAKER (120V 16A S-P) (91861527)
$201.84 / EA
|
|
| Attributed Data | |||
| Add a product to the cart | Show more details | Show more details | Show more details |