Call Us Today: (800) 462-7733
ISOLATING TRANSFORMER 61558-2-6, EN61131-2 SAFETY INSTALLATION SCREW EN CONNECTION TERMINALS SCREW/TAB /B W(%) 5 IP00 TYPE OF PROTECTION CL. I TA/ISOKL 60 GR./SHIELD WNG. II0 /0 F(HZ) 50...60 VECTOR DC) 24 ISEC(A DC) 10 UPRI(V) 400-230+/-15 USEC(V PN(KW) 0,24 POWER SUPPLY PHASES 1

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

4AV2400-2EB00-0A

$3,010.01 / EA

manufacturer discounts
learn about discounts

  • $2,698.63 for $1,500.00+
  • $2,594.84 for $2,500.00+
  • $2,491.04 for $3,500.00+

In stock (0)
Lead time: over 7 days
may be longer on small orders

ISOLATING TRANSFORMER 61558-2-6, EN61131-2 SAFETY INSTALLATION SCREW EN CONNECTION TERMINALS SCREW/TAB /B W(%) 5 IP00 TYPE OF PROTECTION CL. I TA/ISOKL 60 GR./SHIELD WNG. II0 /0 F(HZ) 50...60 VECTOR DC) 24 ISEC(A DC) 10 UPRI(V) 400-230+/-15 USEC(V PN(KW) 0,24 POWER SUPPLY PHASES 1

ISOLATING TRANSFORMER 61558-2-6, EN61131-2 SAFETY INSTALLATION SCREW EN CONNECTION TERMINALS SCREW/TAB /B W(%) 5 IP00 TYPE OF PROTECTION CL. I TA/ISOKL 60 GR./SHIELD WNG. II0 /0 F(HZ) 50...60 VECTOR DC) 24 ISEC(A DC) 10 UPRI(V) 400-230+/-15 USEC(V PN(KW) 0,24 POWER SUPPLY PHASES 1

150

UPC
754554888194
UNSPSC
39121026
Country of Origin
CZ
Ambient temperature / rated value:
60 °C
Certificate of suitability:
CE
Construction form of the iron core:
EI120/72
Depth:
128 m
Electrical input frequency / maximum:
60 Hz
Electrical input frequency / minimum:
50 Hz
Height:
170 m
Input current / _1 / rated value:
0.85 A
Input current / _2 / rated value:
0.89 A
Input current / _3 / rated value:
0.92 A
Input current / _4 / rated value:
1.46 A
Input current / _5 / rated value:
1.54 A
Input current / _6 / rated value:
1.65 A
Input voltage / _1 / rated value:
415 V
Input voltage / _2 / rated value:
400 V
Input voltage / _3 / rated value:
385 V
Input voltage / _4 / rated value:
245 V
Input voltage / _5 / rated value:
230 V
Input voltage / _6 / rated value:
215 V
Input voltage / maximum:
439.90 V
Input voltage / minimum:
193.5 V
Operating resource protection class:
I
Output current / _1 / rated value:
10 A
Output current / at DC / at 40 °C / rated value / maximum:
12 A
Output current / at DC / at 60 °C / rated value / maximum:
10 A
Output voltage / _1 / rated value:
24 V
Output voltage / of the measurement signal / at analog output / at DC / maximum:
28.8 V
Output voltage / of the measurement signal / at analog output / at DC / minimum:
20.4 V
Phase number / of the inputs:
1
Protection class IP:
IP00
Relative residual ripple / of the output voltage 1 / for main current circuit / maximum:
5 %
Thermal class / acc. to IEC 60085:
B
Type of current / _1 / at output:
DC
Type of current / of the inputs:
AC
Vector group:
Ii0
Width:
120 m
Compare With Similar Items
TRANSFORMER SITAS PHASES 1 PN/PN(S6)(KVA) 0.63 /2.35 UPRI(V) 230+/-5% USEC(V) 110 ISEC(A) 5.73 F(HZ) 50...60 VECTOR GR./SHIELD WNG. II0 /0 TA/ISOKL 40 /B IP00 TYPE OF TERMINALS SCREW/TAB CONNECTION INSTALLATION SCREW EN 61558-2-1. -2-2. -2-4 UL/CSA-R...

4AM52424TJ100FA0

$1,880.97 /ea

TRANSFORMER SITAS PHASES 1 PN/PN(S6)(KVA) 0.63 /2.35 UPRI(V) 230+/-5% USEC(V) 110 ISEC(A) 5.73 F(HZ) 50...60 VECTOR GR./SHIELD WNG. II0 /0 TA/ISOKL 40 /B IP00 TYPE OF TERMINALS SCREW/TAB CONNECTION INSTALLATION SCREW EN 61558-2-1. -2-2. -2-4 UL/CSA-RECOGNIZED ( ) >CONTROL CIRCUIT TRANSFORMER ( ) ISOLATION TRANSFORMER ( )>

Attributed Data Included
Mounting type screws Yes
Product function / Insulation monitoring No Yes
Product function / Short-circuit and overload proof No Yes
Product function / Temperature monitoring No Yes
Type of electrical connection / at input / for main current circuit screw-typeterminals/tabterminals Yes
Type of electrical connection / at output / for main current circuit screw-typeterminals/tabterminals Yes
TRANSFORMER SITAS PHASES 1 PN/PN(S6)(KVA) 0,5 /2,02 UPRI(V) 110 USEC(V) 110 ISEC(A) 4,545 F(HZ) 50...60 VECTOR GR./SHIELD WNG. II0 /0 TA/ISOKL 40 /B IP00 TYPE OF TERMINALS SCREW/TAB CONNECTION INSTALLATION SCREW EN 61558-2-2, -2-4 UL/CSA-RECOGNIZED >...

4AM4842-1JJ10-0FA0

$1,346.76 /ea

TRANSFORMER SITAS PHASES 1 PN/PN(S6)(KVA) 0,5 /2,02 UPRI(V) 110 USEC(V) 110 ISEC(A) 4,545 F(HZ) 50...60 VECTOR GR./SHIELD WNG. II0 /0 TA/ISOKL 40 /B IP00 TYPE OF TERMINALS SCREW/TAB CONNECTION INSTALLATION SCREW EN 61558-2-2, -2-4 UL/CSA-RECOGNIZED >CONTROL CIRCUIT TRANSFORMER >ISOLATION TRANSFORMER

Attributed Data Included
Mounting type screws Yes
Product function / Insulation monitoring No Yes
Product function / Short-circuit and overload proof No Yes
Product function / Temperature monitoring No Yes
Type of electrical connection / at input / for main current circuit screw-typeterminals/tabterminals Yes
Type of electrical connection / at output / for main current circuit screw-typeterminals/tabterminals Yes
SITOP PSU300E 24 V/5 A STABILIZED POWER SUPPLY INPUT 3 400-500 V AC OUTPUT 24 V/5 A DC